How to Design a Basic Hydraulic System: Requirements, Circuit, and Checks
Plan a basic hydraulic system from motion requirements to actuator, pump, valve, return-flow, and thermal checks, with a clear design review checklist.
Design a basic hydraulic system by defining the machine's required motion, translating that motion into actuator pressure and flow, and choosing a supply and control arrangement that works in every operating state. Then check the return paths, fluid condition, heat balance, protection, and acceptance criteria. The result should be a documented system proposal with calculations and explicit review responsibilities.
This guide follows a conventional open-circuit arrangement for a single actuator. It explains the design sequence rather than supplying a ready-to-build machine drawing. Vertical lifting, hazardous load holding, accumulators, high-speed motion, and specialized process equipment need additional application-specific engineering. Even a simple horizontal mechanism requires a defined response to stopping, loss of power, and component faults.
Contents
- Define the machine task and design boundary
- Write a state and sequence table
- Select the actuator from the load
- Choose a compatible pump and valve concept
- Build the pressure, flow, and power budget
- Check every supply, return, and drain path
- Plan fluid, reservoir, filtration, and cooling together
- Define pressure protection and safe operating states
- Produce drawings and a reviewable component list
- Plan commissioning and acceptance before assembly
- Frequently asked questions
Define the machine task and design boundary
Begin with the physical task. A useful requirement says what must move, against what load, over what distance, in what time, and how often. “Use a 5 kW power pack” is already a proposed solution and may hide the real need.
| Requirement | Record before selecting components |
|---|---|
| Mechanical work | Load direction, magnitude, travel and linkage geometry |
| Motion quality | Speed range, acceleration, stopping distance and positioning needs |
| Cycle | Order, overlap, holds, idle periods and starts |
| Site conditions | Electrical supply, temperature, space, noise and cooling utilities |
| Fluid requirements | Compatibility, operating viscosity and contamination limits |
| Interfaces | Mechanical mounting, controls, pipes and maintenance access |
| Acceptance | Measurable performance and the conditions for demonstrating it |
Separate the hydraulic supply boundary from the machine boundary. Identify who designs the actuator mounting, electrical controls, safeguarding, and load-support functions.
The terminology in what a hydraulic system is helps distinguish the energy source from the complete machine function. Application examples in industrial hydraulic systems can help frame the task.

Write a state and sequence table
A circuit must behave sensibly between movements as well as during them. Describe each state before choosing valve symbols.
| State | Intended actuator behavior | Supply/control question |
|---|---|---|
| Start-up | No unintended movement | How is the circuit made ready without creating motion? |
| Advance | Move at the required speed and force | What pressure and flow are needed at the actuator? |
| Hold | Maintain the required position or force | What leakage, drift, energy and load support are acceptable? |
| Return | Move back under controlled conditions | What are the return-flow and overrunning-load conditions? |
| Idle | Await the next command | Does supply unload, reduce delivery, or stop? |
| Stop or fault | Reach the defined safe condition | What happens to stored energy and externally driven movement? |
Add timing, permissive conditions, and the signals that allow transitions. Do not assume that losing the electrical command produces a safe mechanical state. A spring-centered valve has a defined hydraulic position, but the resulting machine behavior depends on its connections and loads.
For multiple functions, mark which demands overlap. The sequence determines whether flows are added, shared, or supplied separately. This is more useful than simply summing all component nameplate maxima.
Select the actuator from the load
Determine the force or torque at the actuator connection, including geometry, friction, inertia, and gravity where applicable. For a cylinder, establish the bore, rod, stroke, and mounting as a preliminary combination.
The basic relations are force = pressure × effective area and flow = area × speed, with appropriate units. A real double-acting cylinder also has opposing chamber pressure and friction. Its cap-end and annular areas differ, so extension and retraction must both be evaluated.
The guide how to size a hydraulic cylinder develops those calculations with backpressure and return-flow checks.
Keep the actuator decision provisional until the supply and return paths have been assessed. If the return circuit produces more backpressure than assumed, available force changes. If the machine requires faster motion, the selected bore may increase pump demand beyond the available power or acceptable losses.
A cylinder is also a structural installation. Its pressure-force capability does not prove rod stability or mounting strength.
Choose a compatible pump and valve concept
For a basic constant-speed, fixed-displacement pump, flow continues while the shaft turns. The circuit needs an appropriate destination for that flow in neutral. One conceptual option is a tandem-center directional valve: P connects to T, while A and B are blocked in the center position.
That P-to-T path can unload the pump at the pressure needed to overcome the path's resistance. It is not zero-loss operation. Blocked work ports also do not guarantee leak-free position holding or a safety-rated load restraint.
Another concept uses a suitable pressure-compensated variable-displacement pump with a compatible closed-center control arrangement. When demand reduces, the pump can reduce displacement. Standby losses and pressure-control behavior still require assessment.
These are starting concepts, not interchangeable component recipes. A fixed-displacement pump feeding blocked flow without an unloading route may discharge continuously through a relief valve, converting substantial input into heat. A variable pump also needs its control settings and pressure protection coordinated according to the selected equipment.
Parker's HPU manual provides product-specific guidance on unloading and pressure-control coordination. Use the actual unit's schematic and manual when applying those principles. Source: HPU installation and maintenance.

Build the pressure, flow, and power budget
Track pressures at named locations. The supply must cover the actuator's requirement plus the relevant supply-path losses. Return pressure belongs in the actuator force balance. Do not add or subtract an unspecified “system pressure” everywhere.
For steady flow:
Hydraulic power (kW) = pressure difference (bar) × flow (L/min) ÷ 600
Consider an illustrative supply duty with a constant delivered flow of 15 L/min:
| Stage | Duration | Pump pressure rise | Hydraulic output |
|---|---|---|---|
| Work | 4 s | 80 bar | 2.00 kW |
| Return | 4 s | 40 bar | 1.00 kW |
| Unloaded idle | 12 s | 5 bar | 0.125 kW |
These are assumed pump operating points, not values derived from a particular actuator. They show how to organize a budget.
At the work point, an assumed pump overall efficiency of 0.85 gives 2.00 / 0.85 = 2.35 kW of shaft input. Electrical input additionally depends on the motor and drive. Starting, overload capability, continuous rating, ambient conditions, and the real efficiency map must be evaluated before selecting a motor.
Across the 20-second example cycle, average hydraulic output is:
(2.00 × 4 + 1.00 × 4 + 0.125 × 12) / 20 = 0.675 kW
This average is not the required cooler capacity. Some output may become useful work; some becomes heat, and other losses occur upstream. Establish where energy goes before calculating heat rejection.
Peak pressure and peak flow must also be achievable together. Use power-unit selection to translate the complete duty into an equipment request.

Check every supply, return, and drain path
Draw the intended flow path for every state. Include paths that do not carry the same flow or pressure as the main supply.
| Path | Checks |
|---|---|
| Pump inlet | Available inlet conditions, fluid viscosity and suction losses |
| Pressure supply | Peak and continuous flow, losses, ratings and transients |
| Actuator return | Actual displaced flow and the resulting backpressure |
| Case drain or pilot drain | Manufacturer limits and permitted routing |
| Cooling/filter loop | Its own flow, pressure limits, bypasses and control |
| Isolated volume | Possible pressure from temperature or external loading |
In ordinary single-rod cylinder retraction, cap-end return flow can exceed the flow entering the smaller annular chamber. Simultaneous returns or accumulator discharge can create other peaks. Bosch Rexroth's design guidance specifically identifies return and decompression flow as supply-unit design inputs. Source: HPU design considerations.
Choose pipe and hose sizes using actual length, fittings, fluid properties, allowable losses, and component limits. A universal line-velocity rule cannot replace that assessment. Check installation constraints such as bend radius, movement, vibration, abrasion, and service access.
A case-drain line must not be treated as an arbitrary spare return connection. Its permitted pressure can differ greatly from the main circuit.
Plan fluid, reservoir, filtration, and cooling together
Fluid-management decisions influence one another.
The reservoir must accommodate changing system inventory while maintaining the intended level and inlet conditions. Determine usable volume from actuator positions, other storage devices, thermal expansion, and the chosen tank arrangement. Nominal tank capacity alone does not establish usable capacity.
Select the fluid and contamination target from the actual component requirements and environment. Filtration must achieve the required cleanliness without introducing unacceptable pressure loss or inlet restriction. Filter location, efficiency, flow range, bypass behavior, indicators, and servicing all matter.
Thermal design starts with the losses over the duty cycle. Some losses heat the fluid directly; some motor or drive losses enter the surrounding air. External sources and gravity-driven loads can also affect the balance.
HAWE describes system temperature as the interaction of heat input, thermal storage, and heat transfer to the surroundings. Source: hydraulic heat balance.
A cooler must reject the required heat at the actual fluid flow and available temperature difference. HYDAC's performance guidance relates air-cooler capability to oil flow and the difference between entering oil and entering air temperatures. Source: Standard Coolers catalogue.
Therefore, a larger tank or a nominal cooler “kW rating” is not a complete thermal design. Check the hottest expected inlet air or cooling water, acceptable oil conditions, installation airflow, fouling allowance, and the actual cooling circuit.

Define pressure protection and safe operating states
List the hazards and the hydraulic functions required to control them. Overpressure protection, holding a suspended load, preventing unexpected movement, and isolating stored energy are different tasks.
A main relief valve protects only the circuit volumes that can communicate with it under the relevant conditions. Closed valves may isolate other volumes. External forces can create chamber pressure independently of pump delivery.
Specify the intended behavior during loss of electrical power, loss of a command, loss of pressure, and foreseeable component failures. Determine whether the load needs mechanical support or a dedicated load-control arrangement. These decisions require competent machinery assessment.
Do not treat a pressure switch as a relief valve, a stopped pump as proof of zero pressure, or an emergency-stop button as a complete isolation procedure. Controls and hydraulic hardware must jointly achieve the defined behavior.
The general scope of ISO 4413 addresses hydraulic systems and components used on machinery. Applying its complete requirements requires the relevant standard text and an application-specific review, not merely placing its number on a drawing.
Produce drawings and a reviewable component list
Turn the concept into documents that another engineer can check.
The hydraulic schematic should identify components, ports, pressure zones, normal valve positions, drain routes, and measurement points. Include the states or notes needed to explain functions that are not obvious from a static drawing.
The component list should record the basis for selection, not just catalogue numbers.
| Document | Minimum useful content |
|---|---|
| Requirements and sequence | Loads, motions, conditions, states and timing |
| Calculations | Force, flow, pressure losses, power and thermal assumptions |
| Hydraulic schematic | Identifiers, connections, functions and measurement locations |
| Component schedule | Ratings, materials, interfaces and selection references |
| Control description | Commands, permissives, alarms and stopping behavior |
| Installation information | Mountings, lines, access and environmental constraints |
| Verification plan | Test conditions, limits, records and responsible reviewers |
Keep preliminary assumptions visible. If a valve pressure-loss curve, cooler selection, or actuator rating is still unconfirmed, identify it as an open item. A complete-looking schematic must not conceal an incomplete calculation.
Plan commissioning and acceptance before assembly
Define how the design will be demonstrated before equipment is assembled. This makes missing instrumentation, test access, and acceptance criteria easier to identify.
Pre-commissioning review should cover the approved drawings, component identities, mechanical mounting, fluid preparation, electrical interfaces, protection settings, and the manufacturer's start-up requirements. Implementation must follow an approved procedure for the actual equipment.
Performance verification should compare measured actuator speed and force-related pressures against the requirement, at specified fluid conditions and loads. Check supply and return behavior together. Record stabilized thermal behavior over the representative duty and relevant environment, rather than concluding from a brief unloaded run.
The acceptance matrix should state the requirement, measurement location, test condition, permissible result, and reviewer. Fault-response checks must themselves be planned so that testing does not introduce uncontrolled motion or pressure.
Retain as-built documentation and baseline measurements. They support future diagnosis when a changed cycle, component replacement, or operating environment alters performance. A test-equipment requirement can be developed with the test bench buyer's checklist.
Frequently asked questions
Should I select the pump first?
Start with load, motion, and sequence. These establish the actuator and supply requirements; the choices are then refined together.
Can a fixed-displacement pump use a closed-center valve?
Only within an architecture that properly manages its continuing flow, such as an appropriately engineered unloading arrangement. Blocking delivery without addressing the flow is not a complete design.
Can the relief valve control normal cylinder speed?
A relief valve is not a general substitute for the intended flow-control strategy. Continuous relief flow can waste energy and generate heat.
Can I size the tank from pump flow alone?
No. Fluid inventory, level changes, inlet conditions, contamination management, heat balance, and installation also matter.
What should be ready for design review?
A requirement sheet, state table, numbered schematic, calculation record, component schedule, and acceptance plan. These let reviewers assess how the system meets its task and which decisions remain unresolved.