A hydraulic power unit may have an electric motor running and a pump turning, yet the pressure gauge still shows little or no pressure.
When this happens, it is tempting to assume that the hydraulic pump has failed.
That is only one possibility.
A hydraulic power unit can fail to build pressure because the pump is not receiving oil, the motor or coupling is not driving the pump correctly, the pump is rotating in the wrong direction, the relief or unloading valve is bypassing flow, the directional valve provides an open path to tank, the pump has not been properly primed, or excessive internal leakage exists somewhere in the circuit.
The most important troubleshooting principle is:
Pressure can only develop when pump flow meets resistance.
If the pump produces flow but that flow returns freely to the reservoir, the system may show very little pressure even though the pump itself is operating.
A good diagnosis should therefore answer two questions first:
- Is the hydraulic power unit actually producing flow?
- If flow exists, where is that flow going when pressure should be building?
This guide explains a practical troubleshooting sequence.
目次
- First: Is Low Pressure Actually a Fault?
- Separate the Problem: No Flow or No Pressure?
- Step 1: Make the System Safe
- Step 2: Confirm the Pressure Measurement
- Step 3: Check the Electric Motor or Prime Mover
- Step 4: Check Pump Rotation
- Step 5: Check the Pump-to-Motor Coupling
- Step 6: Check Hydraulic Fluid Level
- Step 7: Inspect the Pump Suction Path
- Step 8: Check Whether the Pump Is Properly Primed
- Step 9: Check the Relief Valve
- Step 10: Check Unloading Valves and Bypass Paths
- Step 11: Check the Directional Control Valve
- Step 12: Check Pressure-Compensated or Load-Sensing Pump Controls
- Step 13: Look for Major Internal Leakage
- Step 14: Evaluate the Pump Condition
- Step 15: Compare Cold and Warm Operation
- A Practical Troubleshooting Sequence
- Symptom-Based Diagnosis
- Common Troubleshooting Mistakes
- When Should the Hydraulic Pump Be Repaired or Replaced?
- Keep Observations Separate from Adjustments
- 概要
- よくある質問
- 技術情報源および参考文献
- 関連記事
First: Is Low Pressure Actually a Fault?
Before diagnosing the hydraulic power unit, understand how the circuit is designed to operate.
Some hydraulic systems are intentionally at low pressure when no actuator is working.
For example, an open-center directional valve may allow pump flow to return to the reservoir at low pressure while the valve is in neutral.
In this condition:
- The pump is running.
- Oil is circulating.
- The pressure gauge may show only low backpressure.
- High pressure develops only when an actuator is commanded and the load creates resistance.
This may be normal.
The real fault is when the system should be producing pressure under load but cannot reach the required value.
Therefore, always compare the measured pressure with:
- The hydraulic schematic
- The machine operating condition
- The specified working pressure
- The relief-valve setting
- The pump-control design
Do not diagnose a low neutral pressure as a failure without understanding the circuit.
Separate the Problem: No Flow or No Pressure?
This is the most useful first diagnostic step.
Condition A: No Flow and No Pressure
考えられる原因としては、次のようなものがあります:
- Electric motor not running
- Incorrect electrical supply
- Broken pump drive coupling
- Pump shaft not turning
- Wrong pump rotation
- Low reservoir level
- Blocked suction line
- Blocked suction strainer
- Reservoir breather blocked
- Pump not primed
- Air entering the suction line
- Severely damaged pump
If the pump is not moving oil, the system cannot build useful pressure.
Condition B: Flow Exists but Pressure Will Not Build
考えられる原因としては、次のようなものがあります:
- No meaningful resistance in the circuit
- Relief valve set too low
- Relief valve stuck open
- Unloading valve remaining open
- Directional valve providing an unintended path to tank
- Pressure-control valve incorrectly adjusted
- Pump compensator or load-sensing control problem
- Major internal leakage
- Worn hydraulic pump
This distinction prevents technicians from immediately replacing the pump.

Step 1: Make the System Safe
Hydraulic troubleshooting can involve:
- 高圧
- 蓄積された水力エネルギー
- 熱した油
- Moving machinery
- 吊り荷
- 電力
Before testing:
- Lower or mechanically support suspended loads.
- Follow the machine lockout procedure.
- Release stored hydraulic pressure where required.
- Treat accumulators as stored-energy devices.
- Never loosen fittings to “see if pressure is there.”
- Never use bare hands to search for a hydraulic leak.
- Use pressure-rated test equipment at approved test points.
Troubleshooting should be performed by qualified personnel who understand the machine and hydraulic circuit.
Step 2: Confirm the Pressure Measurement
Before diagnosing the hydraulic system, confirm that the pressure reading itself is reliable.
Check:
- Is the pressure gauge installed at the correct test point?
- Is the gauge range suitable for the expected pressure?
- Is the gauge damaged?
- Is an isolation valve closed?
- Is the pressure sensor receiving correct electrical power?
- Is the displayed pressure coming from the correct sensor?
A failed gauge or incorrectly located test point can make a healthy system appear to have no pressure.
If possible, compare the reading with a known-good calibrated gauge or approved diagnostic instrument.
Do not assume the displayed value is correct simply because it appears on the machine screen.
Step 3: Check the Electric Motor or Prime Mover
The hydraulic pump must be driven correctly.
Check:
- Is the electric motor running?
- Is the engine or PTO actually driving the pump?
- Is the electrical supply correct?
- Is the motor running at the expected speed?
- Is the pump shaft rotating?
- Is the motor protection device tripped?
A motor can sometimes make noise without properly driving the pump.
For DC hydraulic power units, weak batteries, voltage drop, damaged cables, or poor electrical connections can reduce motor performance.
For AC units, supply voltage, phase condition, motor connection, and starter condition should be checked according to the equipment documentation.
Step 4: Check Pump Rotation
Hydraulic pumps are designed for a specified direction of rotation.
If the pump rotates in the wrong direction, it may:
- Fail to pump correctly
- Produce little or no flow
- Fail to prime
- Make abnormal noise
- Suffer damage
This is especially relevant after:
- Motor replacement
- Electrical rewiring
- Pump replacement
- New system commissioning
Do not determine rotation only by looking at the motor fan or assuming all pumps use the same direction.
Confirm pump rotation from the pump documentation and shaft orientation.
Step 5: Check the Pump-to-Motor Coupling
The motor may be running while the pump shaft is not.
A failed or damaged coupling can produce exactly this symptom:
Motor running + No useful pump flow + No system pressure
Check the coupling according to the manufacturer’s service procedure.
Possible problems include:
- Broken coupling element
- Sheared coupling
- Loose hub
- Misalignment
- Damaged pump shaft
If the coupling failed, determine why.
Simply replacing a failed coupling without checking pump seizure, alignment, or overload may lead to another failure.
Step 6: Check Hydraulic Fluid Level
The pump must have an adequate fluid supply.
A low reservoir level can allow the pump to draw air instead of oil.
Possible symptoms include:
- No pressure
- Low pressure
- Intermittent pressure
- Pump noise
- Foamy oil
- Jerky actuator movement
Check the fluid level using the manufacturer’s specified machine condition.
Some reservoirs must be checked with cylinders retracted; others may have different instructions.
Also check for evidence of unexpected oil loss.
A low level may be a symptom of an external leak elsewhere in the system.
Step 7: Inspect the Pump Suction Path
A hydraulic pump cannot build reliable pressure if it cannot receive fluid properly.
Inspect the suction side for:
- Blocked suction strainer
- Restricted suction filter
- Collapsed hose
- Kinked hose
- Closed isolation valve
- Small suction line
- Blocked reservoir outlet
- Blocked reservoir breather
- Incorrect oil viscosity
- Air leak at fittings
- Air leak at pump inlet seal
A suction-side air leak is especially difficult to see because it may pull air into the system without leaking oil outward.
Possible symptoms include:
- Pump whining
- Foamy oil
- Cavitation noise
- Unstable flow
- Poor pressure
- Slow actuator movement
The suction side should be checked before condemning the pump.
Step 8: Check Whether the Pump Is Properly Primed
Some hydraulic pumps must be filled or bled correctly during initial startup or after service.
If the pump contains air and cannot establish proper suction, it may fail to deliver normal flow.
This can occur after:
- Replacing the pump
- Draining the reservoir
- Opening the suction line
- Long storage
- Major hydraulic maintenance
Follow the pump manufacturer’s startup and priming procedure.
Do not run a pump dry in an attempt to make it prime.
Insufficient lubrication during dry running can damage the pump quickly.
Step 9: Check the Relief Valve
If the pump produces flow but the hydraulic power unit cannot build pressure, the relief valve is one of the most important components to inspect.
A pressure-relief valve limits maximum system pressure by opening a flow path when pressure reaches its setting.
If the valve:
- Is set too low
- Is stuck open
- Has contamination on the seat
- Has a damaged spring or pilot stage
- Is incorrectly assembled
- Is being held open by another control
pump flow may return to the reservoir before useful system pressure develops.
A clue is that:
- Pump flow exists.
- Oil returns to tank.
- The actuator has little force.
- System pressure stays near the relief or bypass condition.
Do not solve the problem by simply tightening the relief-valve adjustment.
The correct procedure is to compare the valve operation and setting with the machine specification and manufacturer procedure.
Excessively increasing a relief setting can overload pumps, hoses, cylinders, valves, and machine structures.
Step 10: Check Unloading Valves and Bypass Paths
Some hydraulic power units intentionally unload the pump when high pressure is not needed.
Systems may use:
- Unloading valves
- Solenoid unloading valves
- Ventable relief valves
- Accumulator charging circuits
- Pressure-compensated pump controls
If an unloading valve remains open when the system should be working, pump flow may return directly to the reservoir.
考えられる原因としては、次のようなものがあります:
- Electrical fault
- Solenoid not energizing
- Incorrect pilot signal
- 汚染
- Incorrect valve assembly
- Incorrect control logic
When troubleshooting, follow the hydraulic schematic and identify every possible low-resistance path from the pump pressure line back to the reservoir.

Step 11: Check the Directional Control Valve
A directional valve can also prevent pressure from building.
Depending on spool configuration, the valve may connect:
Pump → Tank
when in neutral.
That may be completely normal.
But if the valve remains in an unloading position when an actuator should be working, pressure may stay low.
考えられる原因としては、次のようなものがあります:
- Solenoid not energized
- Incorrect electrical signal
- Stuck spool
- Mechanical linkage problem
- Pilot-pressure problem
- Wrong valve installed
- Incorrect spool type
- Internal damage
Check whether the valve actually shifts to the required operating position when the command is given.
Do not diagnose the valve only from the electrical indicator light. A coil can be energized while the spool fails to move correctly.
Step 12: Check Pressure-Compensated or Load-Sensing Pump Controls
Variable-displacement hydraulic pumps may use:
- Pressure compensators
- Load-sensing controls
- Electronic displacement controls
- Remote pressure controls
These pumps do not behave like simple fixed-displacement gear pumps.
A control problem can cause a variable pump to remain at minimum displacement even when more pressure and flow are required.
Possible issues include:
- Incorrect pressure setting
- Missing load-sense signal
- Blocked control orifice
- Pilot-pressure problem
- Faulty pressure sensor
- Electrical-control problem
- Pump-control contamination
- Incorrect commissioning
Always diagnose these systems according to the pump manufacturer’s control documentation.
Random adjustment of compensators can make troubleshooting more difficult and may create unsafe pressure conditions.
Step 13: Look for Major Internal Leakage
Even when the pump, relief valve, and control valves appear to operate, excessive internal leakage elsewhere can prevent the system from reaching pressure.
Possible leakage locations include:
- Hydraulic cylinder piston seals
- 油圧モーター
- Directional valve
- Pressure-control valve
- Manifold
- Damaged internal seals
- Worn pump
A large internal leakage path effectively becomes another route back to low pressure.
質問:
Where can pump flow go when the system should be loaded?
A hydraulic schematic is extremely useful for answering this question.
Step 14: Evaluate the Pump Condition
A worn or damaged pump may still move some oil but fail to maintain flow as pressure increases.
This can create symptoms such as:
- Acceptable movement with no load
- Very weak actuator under load
- Pressure rises only to a low value
- Pump becomes hot
- Excessive pump noise
- Increased case drain on pumps where case-drain measurement is applicable
Pump condition should be evaluated using the manufacturer’s approved test method.
Pressure alone is often not enough.
Useful diagnostic measurements can include:
- Pump outlet flow
- 圧力
- 速度
- 温度
- Case-drain flow where applicable
A flow test under controlled pressure is often more informative than simply looking at a pressure gauge.
Step 15: Compare Cold and Warm Operation
A system may build acceptable pressure when cold but lose pressure after the oil becomes hot.
Possible reasons include:
- Lower fluid viscosity
- Increased internal leakage
- Worn pump clearances
- Valve leakage
- Cylinder leakage
- Incorrect oil grade
Record:
- Oil temperature
- 圧力
- フロー
- Machine load
before deciding whether the fault is temperature-related.
Do not compare a cold test with a hot test without recording the conditions.

A Practical Troubleshooting Sequence
A useful sequence is:
1. Make the machine safe ↓ 2. Verify the pressure reading ↓ 3. Confirm motor/engine operation ↓ 4. Confirm pump rotation ↓ 5. Check coupling ↓ 6. Check fluid level ↓ 7. Inspect suction path ↓ 8. Confirm pump priming ↓ 9. Check relief/unloading valves ↓ 10. Check directional valve ↓ 11. Check pump control system ↓ 12. Look for major internal leakage ↓ 13. Evaluate pump flow under load ↓ 14. Compare cold and hot operation
This order moves from simple and external causes toward more expensive component failures.
Symptom-Based Diagnosis
Motor Does Not Run
Check:
- Power supply
- Fuses or breakers
- Battery condition
- Wiring
- Motor starter
- Thermal protection
- Control signal
If the pump is not driven, no hydraulic pressure can be generated.
Motor Runs but Pump Has No Flow
Check:
- Coupling
- Pump rotation
- 液面
- Suction line
- Suction strainer
- Pump priming
- Pump damage
Pump Produces Flow but No Pressure
Check:
- Open-center circuit condition
- Relief valve
- Unloading valve
- Directional valve
- Bypass path to tank
- Major internal leakage
- Pump control
System Builds Some Pressure but Not Enough
Check:
- Relief setting
- Pump wear
- 内部漏れ
- 流量需要
- モーター回転数
- Pump control settings
- 油の粘度
- System load
Pressure Is Erratic
Check:
- Air entering suction line
- Low oil level
- Cavitation
- Pressure-control valve instability
- Pump-control problem
- 汚染
- Sensor or gauge problem
Common Troubleshooting Mistakes
Mistake 1: Replacing the Pump First
A failed pump can cause low pressure, but so can:
- Relief-valve bypass
- Open unloading circuit
- Wrong rotation
- Broken coupling
- Low oil
- Blocked suction
- Control-valve problems
Verify the rest of the circuit before replacing an expensive pump.
Mistake 2: Increasing the Relief Pressure Immediately
If the relief valve is already correctly set, increasing it may not solve the problem.
It can instead expose the system to excessive pressure.
Measure first. Adjust only according to the approved specification.
Mistake 3: Looking Only at Pressure
A pressure gauge does not tell you whether the pump is delivering the required flow.
Pressure and flow should often be evaluated together.
Mistake 4: Ignoring the Suction Side
Suction restrictions and air entry can prevent a healthy pump from performing correctly.
Check the reservoir-to-pump path early in the diagnosis.
Mistake 5: Troubleshooting Without the Hydraulic Schematic
The schematic shows possible:
- Bypass paths
- Relief paths
- Unloading circuits
- Load-sense lines
- Pilot circuits
Without it, technicians may replace components without understanding where the oil is actually flowing.
When Should the Hydraulic Pump Be Repaired or Replaced?
Pump repair or replacement becomes more justified when testing confirms:
- Pump drive is correct
- Suction supply is correct
- Relief and unloading circuits are correct
- Control valves are functioning
- Pump speed is correct
- Major external circuit leakage has been eliminated
- Pump cannot deliver specified flow at the required pressure
The final decision should consider:
- ポンプの種類
- Damage
- 汚染
- Repair cost
- Parts availability
- Required reliability
If a pump has failed, the cause of the failure should also be investigated.
Replacing the pump without correcting contamination, suction problems, misalignment, or overpressure can cause the replacement pump to fail again.
Keep Observations Separate from Adjustments
Record command state, pressure location, fluid temperature, available flow and drive condition before concluding that a component has failed. A relief or pump-control setting is not a diagnostic substitute. Electrical work, pressure adjustment and loaded testing require the approved procedure and qualified personnel.
概要
A hydraulic power unit that does not build pressure does not automatically have a failed pump.
The most common causes fall into several groups:
- Motor or pump drive problem
- Wrong pump rotation
- Low fluid level
- Suction restriction
- Air entering the pump
- Pump not primed
- Relief valve bypass
- Unloading valve bypass
- Directional-valve configuration
- Pump-control problem
- Major internal leakage
- Worn or damaged pump
The key troubleshooting principle is:
Find out whether the pump is producing flow, then determine where that flow goes when pressure should be building.
A systematic diagnosis usually saves more time than replacing components one by one.
Start with simple checks, use the hydraulic schematic, measure both pressure and flow where appropriate, and only adjust pressure controls according to approved specifications.
よくある質問
Why is my hydraulic power unit running but not building pressure?
Possible causes include a relief or unloading valve bypassing flow, an open path to tank, insufficient pump flow, suction problems, incorrect pump rotation, a damaged coupling, pump-control problems, or excessive internal leakage.
Can a hydraulic pump have flow but no pressure?
Yes. A pump can produce flow while system pressure remains low if the oil has a low-resistance path back to the reservoir. Pressure develops when flow meets resistance.
Can a relief valve cause low hydraulic pressure?
Yes. If a relief valve is set too low, stuck open, contaminated, or incorrectly controlled, pump flow may bypass to tank before the required pressure is reached.
Can low hydraulic oil cause no pressure?
Yes. If the oil level is low enough for the pump to draw air or lose suction, the pump may fail to produce normal flow and pressure.
Can wrong pump rotation cause no pressure?
Yes. A pump operating in the wrong direction may fail to pump correctly and may be damaged. Rotation should be confirmed from the pump manufacturer’s documentation.
Why does my hydraulic system lose pressure when hot?
As hydraulic oil temperature increases, viscosity generally decreases. Internal leakage through worn pumps, valves, cylinders, or other clearances may become more noticeable.
How do I know if the hydraulic pump is bad?
Do not diagnose the pump from pressure alone. Verify pump drive, suction supply, relief and unloading paths, valve condition, and then measure pump performance according to the manufacturer’s approved test procedure.
Should I increase the relief valve setting if pressure is low?
Not without confirming the correct system specification and identifying the fault. Increasing the relief setting can overload system components and create a safety hazard.
技術情報源および参考文献
ここで論じた範囲および技術的な違いを裏付ける情報源: Parker Hydraulic Power Units Installation and Maintenance Manual HY28-2600-550-M1/USA;Parker Denison Vane Pump Instructions HY29-0036-M1/UK;Webtec Digital Hydraulic Tester DHT Series。 詳細な規格条項、適用範囲、および機械固有の手順については、使用前に技術的な確認が必要です。.
関連記事
申請書の審査についてサポートが必要ですか? 技術審査のために、運転条件、負荷および動作要件、図面をご用意ください。.
この油圧に関する知識を応用する上で、お手伝いが必要ですか?
図面、写真、使用圧力、機器の詳細、または用途に関するご質問などをお送りください。.