{"id":868,"date":"2026-11-19T14:05:51","date_gmt":"2026-11-19T14:05:51","guid":{"rendered":"https:\/\/askhydraulic.com\/?p=868"},"modified":"2026-11-19T14:05:51","modified_gmt":"2026-11-19T14:05:51","slug":"double-rod-hydraulic-cylinder","status":"publish","type":"post","link":"https:\/\/askhydraulic.com\/fr\/double-rod-hydraulic-cylinder\/","title":{"rendered":"Double-Rod Hydraulic Cylinder: Equal Areas, Motion, and Installation"},"content":{"rendered":"<style>.postid-868 .detail-hero-visual img{object-fit:contain}.postid-868 .detail-hero-copy h1{letter-spacing:0;overflow-wrap:anywhere}.ah-published-article{max-width:960px;min-width:0;margin:0 auto}.ah-published-article h2.wp-block-heading{margin:44px 0 16px;font-size:28px;line-height:1.3;letter-spacing:0;scroll-margin-top:110px}.ah-published-article h3.wp-block-heading{margin:28px 0 12px;letter-spacing:0;scroll-margin-top:110px}.ah-published-article p{margin:14px 0}.ah-published-article ul,.ah-published-article ol{margin:16px 0 24px;padding-left:26px}.ah-published-article li+li{margin-top:6px}.ah-published-article .wp-block-image{margin:30px 0}.ah-published-article .wp-block-image img{display:block;width:100%;height:auto;object-fit:contain}.ah-published-article figcaption{font-size:14px;line-height:1.6;color:#52616b;margin-top:10px;text-align:left}.ah-published-article .wp-block-table{max-width:100%;margin:26px 0;overflow-x:auto}.ah-published-article table{width:100%;min-width:520px;border-collapse:collapse;font-size:15px;line-height:1.6}.ah-published-article th,.ah-published-article td{padding:12px 14px;border:1px solid #d9dfe4;text-align:left;vertical-align:top;overflow-wrap:anywhere}.ah-published-article th{background:#25333d;color:#fff;font-weight:700}.ah-published-article tbody tr:nth-child(even){background:#f3f6f8}.ah-published-article .wp-block-details{margin:26px 0;padding:16px 0;border-top:1px solid #d9dfe4;border-bottom:1px solid #d9dfe4}.ah-published-article summary{cursor:pointer;font-weight:700}.ah-published-article a{overflow-wrap:anywhere}.ah-published-article pre{white-space:pre-wrap;overflow-wrap:anywhere;max-width:100%;font-size:16px;line-height:1.7;padding:18px;background:#f3f6f8;color:#25333d;border-radius:4px}.ah-published-article blockquote{margin:24px 0;padding:4px 20px;border-left:3px solid #c5cdd2;font-style:normal}@media(max-width:640px){.ah-published-article h2.wp-block-heading{font-size:24px;margin-top:34px}.ah-published-article h3.wp-block-heading{font-size:20px}.ah-published-article th,.ah-published-article td{padding:10px}.ah-published-article .wp-block-image{margin:24px 0}}.postid-868 .detail-hero-visual{aspect-ratio:3\/2;min-height:0;align-self:center}.postid-868 .ah-published-article .wp-block-heading{scroll-margin-top:180px}<\/style>\n\n\n\n<div class=\"wp-block-group ah-published-article\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n\n<p class=\"wp-block-paragraph\">A double-rod hydraulic cylinder has a rod projecting from each end of the cylinder body. In the common arrangement considered here, both rod ends belong to one piston assembly and move together. The layout can provide equal effective areas on the two sides, but only when the rod diameters are equal. That condition helps explain equal ideal force and speed in opposite directions; it does not create two independently controlled outputs. Understanding the distinction matters when interpreting a drawing, comparing a replacement, or reserving space around a machine. Start with the internal geometry, then check the pressures, flows, mechanical connections, and complete travel envelope before treating the two ends as equivalent.<\/p>\n\n\n\n<details class=\"wp-block-details is-layout-flow wp-block-details-is-layout-flow\"><summary>Sommaire<\/summary>\n\n<ol><li><a href=\"#one-piston-assembly-can-have-two-exposed-rod-ends\">One piston assembly can have two exposed rod ends<\/a><\/li><li><a href=\"#equal-areas-require-equal-rod-diameters\">Equal areas require equal rod diameters<\/a><\/li><li><a href=\"#an-ideal-equal-area-example\">An ideal equal-area example<\/a><\/li><li><a href=\"#two-rod-ends-need-two-motion-envelopes\">Two rod ends need two motion envelopes<\/a><\/li><li><a href=\"#hydraulic-symmetry-does-not-guarantee-mechanical-equivalence\">Hydraulic symmetry does not guarantee mechanical equivalence<\/a><\/li><li><a href=\"#double-rod-cylinder-questions-answered\">Double-rod cylinder questions answered<\/a><\/li><\/ol>\n\n<\/details>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"one-piston-assembly-can-have-two-exposed-rod-ends\">One piston assembly can have two exposed rod ends<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Imagine a piston moving to the right inside a fixed cylinder body. The right-hand rod extends farther outside its end cover while the left-hand rod withdraws toward the opposite cover. Both ends translate in the same direction relative to the machine. They do not move independently simply because two ends are accessible. A drawing that shows opposite arrows should therefore distinguish fluid routing from the actual direction of the common moving assembly.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cDouble rod\u201d describes this geometry. \u201cDouble acting\u201d describes hydraulic action in both directions. A conventional <a href=\"https:\/\/askhydraulic.com\/fr\/double-acting-hydraulic-cylinder\/\">double-acting cylinder<\/a> can have only one projecting rod, with different effective areas on its two sides. The terms therefore answer different questions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A sectional drawing should identify the piston, both rods, both pressure chambers, and the connection between the moving parts. External photographs may hide one rod behind a guard or a machine interface. Confirm the arrangement before interpreting a product name, and avoid assuming that every assembly uses one continuous, uniform piece of rod material.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly.png\" alt=\"Two rod ends belonging to one moving piston assembly\" class=\"wp-image-870\" srcset=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly.png 1536w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly-300x200.png 300w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly-1024x683.png 1024w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly-768x512.png 768w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-rod-ends-belonging-to-one-moving-piston-assembly-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/a><figcaption class=\"wp-element-caption\">Two rod ends belonging to one moving piston assembly, illustrating the section \u201cOne piston assembly can have two exposed rod ends\u201d.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"equal-areas-require-equal-rod-diameters\">Equal areas require equal rod diameters<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For a simple circular piston with a rod passing through each side, the effective areas are:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Area A = \u03c0 \u00d7 (D\u00b2 \u2212 dA\u00b2) \/ 4.<\/li>\n\n\n<li>Area B = \u03c0 \u00d7 (D\u00b2 \u2212 dB\u00b2) \/ 4.<\/li>\n\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Here D is the working bore diameter; dA and dB are the rod diameters at the respective pressure boundaries. Both areas are annular. Neither side uses the full bore area in this arrangement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The areas are equal when dA equals dB. With consistent units, the signed hydraulic force is pressure A \u00d7 area A minus pressure B \u00d7 area B. For equal areas, this becomes the pressure difference multiplied by that common area. The relationship belongs to <a href=\"https:\/\/askhydraulic.com\/fr\/hydraulic-cylinder-pressure-force-area\/\">pression, force et aire<\/a>; the larger individual pressure alone does not describe the net force.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ideal velocity is inlet flow divided by the receiving chamber&#39;s effective area. HAWE&#39;s <a href=\"https:\/\/www.hawe.com\/it-it\/fluid-lexicon\/detail\/synchronizing-cylinder\/\" target=\"_blank\" rel=\"noopener\">synchronizing cylinder definition<\/a> specifically connects equal velocity to equal rod thickness and the same supplied flow. Different flows can produce different speeds even when the areas match.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders.png\" alt=\"Equal and unequal effective areas in double-rod cylinders\" class=\"wp-image-871\" srcset=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders.png 1536w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders-300x200.png 300w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders-1024x683.png 1024w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders-768x512.png 768w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-equal-and-unequal-effective-areas-in-double-rod-cylinders-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/a><figcaption class=\"wp-element-caption\">Equal and unequal effective areas in double-rod cylinders, illustrating the section \u201cEqual areas require equal rod diameters\u201d.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"an-ideal-equal-area-example\">An ideal equal-area example<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Consider a fictional cylinder with a 63 mm bore and two 25 mm rods. Assume steady incompressible flow, no leakage, no friction, and no acceleration. These are explanatory assumptions, not performance promises.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"min-width:520px;table-layout:fixed\"><thead><tr><th>Quantit\u00e9<\/th><th>Calculation or assumption<\/th><th>Ideal result<\/th><\/tr><\/thead><tbody><tr><td>Effective area on either side<\/td><td>\u03c0 \u00d7 (63\u00b2 \u2212 25\u00b2) \/ 4<\/td><td>2,626.37 mm\u00b2<\/td><\/tr><tr><td>Pressure difference<\/td><td>Assumed across the piston<\/td><td>8 MPa<\/td><\/tr><tr><td>Net hydraulic force magnitude<\/td><td>8 \u00d7 2,626.37<\/td><td>21.01 kN<\/td><\/tr><tr><td>Inlet flow<\/td><td>Assumed at the receiving chamber<\/td><td>8 L\/min<\/td><\/tr><tr><td>Travel speed<\/td><td>133,333.33 mm\u00b3\/s \u00f7 2,626.37 mm\u00b2<\/td><td>50.77 mm\/s<\/td><\/tr><tr><td>Volume for 200 mm travel<\/td><td>2,626.37 \u00d7 200<\/td><td>0.525 L per chamber<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The 8 MPa value is a <strong>difference<\/strong> between chamber pressures. It is not permission to ignore the exhaust-side pressure. Reversing which side has the higher pressure reverses the calculated force direction.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The example also separates a force calculation from a speed calculation. Actual equipment must supply the necessary flow while maintaining the required pressures under load. A pump&#39;s nominal flow and a relief setting do not prove that both example conditions occur together.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Equal areas produce equal swept volumes for equal travel. They do not eliminate fluid compression, hose expansion, valve losses, or leakage. Additional circuit volume also means that the table&#39;s displacement is not a complete reservoir-sizing value.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation.png\" alt=\"Ideal equal-area force and speed calculation\" class=\"wp-image-872\" srcset=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation.png 1536w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation-300x200.png 300w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation-1024x683.png 1024w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation-768x512.png 768w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-ideal-equal-area-force-and-speed-calculation-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/a><figcaption class=\"wp-element-caption\">Ideal equal-area force and speed calculation, illustrating the section \u201cAn ideal equal-area example\u201d.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"two-rod-ends-need-two-motion-envelopes\">Two rod ends need two motion envelopes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Installation planning must include the entire moving envelope on both sides. A clear right-hand working space does not compensate for a left-hand rod striking a bracket during the same movement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Check the fully retracted and extended positions against fixed guards, hoses, fittings, sensors, structures, and any attached tooling. Record the machine datum used for each measurement. A spare rod end still moves even when it performs no intended external work.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second penetration also introduces another rod sealing and wiping location. The <a href=\"https:\/\/askhydraulic.com\/fr\/hydraulic-cylinder-rod-seals\/\">rod seals<\/a> and exposed surfaces must suit the actual contamination and environment on their respective sides. One end can be exposed to debris while the other sits inside a protected enclosure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two rods do not automatically solve side loading. The load path, external guides, alignment, and mounting still require assessment. Review <a href=\"https:\/\/askhydraulic.com\/fr\/hydraulic-cylinder-guidance\/\">cylinder guidance<\/a> when a machine constrains either end; incompatible constraints can impose bending even though the hydraulic area calculation is correct.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder.png\" alt=\"Two-sided motion clearance around a double-rod cylinder\" class=\"wp-image-873\" srcset=\"https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder.png 1536w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder-300x200.png 300w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder-1024x683.png 1024w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder-768x512.png 768w, https:\/\/askhydraulic.com\/wp-content\/uploads\/2026\/11\/hc-bas-033-two-sided-motion-clearance-around-a-double-rod-cylinder-18x12.png 18w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/a><figcaption class=\"wp-element-caption\">Two-sided motion clearance around a double-rod cylinder, illustrating the section \u201cTwo rod ends need two motion envelopes\u201d.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hydraulic-symmetry-does-not-guarantee-mechanical-equivalence\">Hydraulic symmetry does not guarantee mechanical equivalence<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Equal effective areas describe fluid action, not the strength of every mechanical connection. Rod-end threads, attachments, piston connections, and mounting details can govern the permitted load differently on each end.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For example, Parker&#39;s <a href=\"https:\/\/www.parker.com\/content\/dam\/Parker-com\/Literature\/Accumulator---Cooler-Division---Europe\/catalogues\/cylinder\/hmi\/HMI_1150-9-uk.pdf\" target=\"_blank\" rel=\"noopener\">HMI\/HMD catalogue<\/a>, in its double-rod section, identifies a particular joined-rod construction with different strength considerations at the two ends. That is a series-specific reminder to read the applicable drawing and limits, rather than a rule that every double-rod cylinder is asymmetric.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"min-width:520px;table-layout:fixed\"><thead><tr><th>Review item<\/th><th>What equal areas establish<\/th><th>What still needs confirmation<\/th><\/tr><\/thead><tbody><tr><td>Hydraulic force<\/td><td>Same ideal relation at the same differential pressure<\/td><td>Friction, actual pressures, external loads<\/td><\/tr><tr><td>Hydraulic speed<\/td><td>Same ideal speed at equal inlet flow<\/td><td>Valve behavior, leakage, available flow<\/td><\/tr><tr><td>Rod-end loading<\/td><td>No separate mechanical rating<\/td><td>Threads, connections, direction of loading<\/td><\/tr><tr><td>Position control<\/td><td>No automatic accuracy specification<\/td><td>Sensors, controls, compliance, required tolerance<\/td><\/tr><tr><td>Static holding<\/td><td>No guaranteed holding function<\/td><td>Circuit, leakage limits, load-support arrangement<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Utilisez le <a href=\"https:\/\/askhydraulic.com\/fr\/read-hydraulic-cylinder-drawing-specification\/\">cylinder drawing<\/a> to record which dimensions and load directions belong to which end. If both ends engage loads, draw one free-body diagram of the complete moving assembly. Do not assign the full calculated net force to each end as two simultaneous independent capacities.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"double-rod-cylinder-questions-answered\">Double-rod cylinder questions answered<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Do two rods double the output force?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">No. The piston assembly has one net hydraulic force balance. Loads applied through both ends share that balance; adding another accessible rod end does not duplicate the hydraulic energy or force available.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Will equal pressures hold the rod precisely in place?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Equal pressures acting on equal areas give zero ideal net hydraulic force. They do not establish precise position or secure load holding. External forces, leakage, compliance, and the circuit&#39;s actual behavior still matter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Can the two rods be commanded to move separately?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not in the common single-piston arrangement described here. They are mechanically connected parts of one moving assembly. Independent motion requires a different mechanism or additional actuators and controls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Does \u201csynchronizing cylinder\u201d mean it synchronizes several cylinders?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Not necessarily. In the cited definition, the term describes equal directional speed under specified geometric and flow conditions. Coordination of multiple separate cylinders is a different control problem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Before specifying this construction, assemble the sectional drawing, both rod-end details, actual load directions, travel clearances, and required motion behavior. Those details let a technical reviewer distinguish useful hydraulic symmetry from assumptions the cylinder itself cannot guarantee.<\/p>\n\n<\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Understand double-rod hydraulic cylinders, the conditions for equal force and speed, two-sided motion clearance, and why equal areas do not double output.<\/p>","protected":false},"author":2,"featured_media":869,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[26],"tags":[],"class_list":["post-868","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-design-guides"],"acf":[],"_links":{"self":[{"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/posts\/868","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/comments?post=868"}],"version-history":[{"count":1,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/posts\/868\/revisions"}],"predecessor-version":[{"id":874,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/posts\/868\/revisions\/874"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/media\/869"}],"wp:attachment":[{"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/media?parent=868"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/categories?post=868"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/askhydraulic.com\/fr\/wp-json\/wp\/v2\/tags?post=868"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}